QTY |
FOB PRICE |
CIF PRICE
QUANTITY
-
+
PCS
TOTAL COST
$1660Model : IN-C005-1 | Payment Terms : L/C, D/A, D/P, T/T, Western Union, MoneyGram, Other | Delivery Port : Guangzhou | delivery Time : 5-7 days | Product Advantages : Well and High Quality Control, Prompt Delivery, New Product, Welcome customer designs and trademarks, Competitive Prices, Fit for Gifts and Premiums, Earth-friendly Products, In a Variety of Design, Small Order Acceptable, ODM Accepted, OEM Accepted, Other |
Material : Default |
Pcs/Carton : 1 | Packing Size/Carton : 42*32*43 cm | Packing Vol/Carton : 0.06 |
N.W./Carton : 4.0 | G.W./Carton : 6.0 | QTY in 40HQ : 1050 |
QTY in 40GP : 1000 | QTY in 20GP : 416 |
Standard configuration:
HR/PR, NIBP, RR, ECG, SpO2, TEMP, Rechargeable lithium batter
Optional:
Dual TEMP,Dual IBP,ETCO2,Thermal recorder,Wall mount,Trolley
Features:
12.1'' screen with true color, wide viewing angle, high brightness LCD display. |
HR/PR, NIBP, RR, ECG, SpO2, TEMP |
Simple and friendly operating display interface. |
Rechargeable lithium battery provides convenience for patients' moving. |
Playback and browse function for long term waveform and monitor data record. |
Optional printing output function, alarm triggers printing. |
Auto double alarm with audible and visible signals |
Anti-defibrillation, anti-interference from high frequency electric knife |
A full-synchronistic lead multi-channel ECG display |
This medical equipment can be used in ICU, CCU and operation room. |
Suitable for adult,pediatrics and neonate patients. |
Specifications:
ECG
Lead configuration
Standard 3-lead or 5-lead
3-leadRA,LA,LL,Lead method:I,II,III
5-leadRA,LA,LL,RL,V,Lead method:I,II,III,aVR,aVL,aVF,V
Increase ´250,´500,´1000,´2000
HR
Range:
Adult 15 ~ 300bpm (beat/minute)
Neonatal baby/children 15 ~ 350 bpm(beat/minute)
Precision±1% or ±1bpm,the larger prevails
Resolution 1 bpm(beat/minute)
Sensitivity:> 200 uV (Peak-to-peak value)
Input Impedance:> 5 (megohm)
Bandwidth
Diagnostic mode0.05~130Hz
Monitoring Mode 0.5~40Hz
Operation mode1~20Hz
Common Mode rejection Ratio
Diagnostic mode> 90 dB
Monitoring Mode > 100 dB
Operation mode> 100 dB
Pole Polarization Vvoltage Range ±300mV
Pacing Pulse Test
Test pacing pulse in accordance with the following conditions:
Amplitude:±2 mV ~ ±700mV
Width: 0.1ms ~ 2ms
Risetime: 10us~100µs
Pacing pulse inhibition
Amplitude:±2 mV ~ ±700mV
Width: 0.1ms ~ 2ms
Risetime: 10us ~ 100µs
Baseline Recovering Time:After defibrillation< 3 seconds
Signal Range:±8 mV (Peak-to-peak value)
Calibrating Signal
1mV(Peak-to-peak value),precision±5%
ST Segment Measuring Volume
Measuring range: -2.0mV ~ +2.0mV
No definition for other ranges.
RESP
Measuring Method:RA-LL impedance
RESP Impedance Measuring Range:0.3~3Ω
Base Impedance Range:200~4000Ω
Bandwidth:0.1~2.5Hz
RESP Rat
Rang
Adult 0~120BrPM
Children and neonatal baby 0~150 BrPM
Resolution 1 BrPM
Precision ±2 BrPM
Asphyxia Alarm:10~40 seconds
NIBP
Measuring Method
Pulse wave oscillometry
Work Mode
Manual/Automatic/STAT
Measuring Interval of Automatic Measuring Mode
1,2,3,4,5,10,15,30,60,90,120,180,240,480 minute(s)
Measuring Time of STAT Mode:5 minutes
PR range:40 – 240 bpm
Overvoltage protection:
Adult mode 300 mmHg
Children mode 240 mmHg
Neonatal baby mode150 mmHg
SpO2
Range 0~100%
Resolution1%
Precision 70~100%:±2 DIGIT
0%~69%:no definition given
PR
Range 20~300bpm
Resolution 1bpm Precision ±3bpm